Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 7 de 7
Filter
1.
Arq. bras. oftalmol ; 72(5): 655-660, set.-out. 2009. ilus, tab
Article in English | LILACS | ID: lil-534186

ABSTRACT

PURPOSE: To evaluate bevacizumab toxicity in neurosensorial retina and retinal pigment epithelium in pigmented rabbit eyes by means of histological studies. METHODS: Thirty eyes of fifteen rabbits were distributed into three groups: sham group (S), that received a 0.1 ml balanced saline solution (BSS) intravitreal injection (10 eyes); group 1, that received a 1.25 mg (0.1 ml) bevacizumab intravitreal injection (10 eyes); and group 2, that received a 2.5 mg (0.1 ml) bevacizumab intravitreal injection (10 eyes). Rabbits were sacrificed 90 days after the procedure and both eyes of each rabbit were enucleated. A histological examination of neurosensorial retina and retinal pigmented epithelium (RPE) was performed. Its morphological features and layer thickness were also analyzed. RESULTS: No histological differences in neurosensorial retina or in retinal pigmented epithelium were found and layer thickness did not differ significantly between balanced saline solution-injected eyes and bevacizumab-injected eyes. CONCLUSION: After a 90-day follow-up period, a single 1.25 or 2.5 mg bevacizumab intravitreal injection did not lead to toxic damage in the neurosensorial retina and retinal pigment epithelium of pigmented rabbit eyes, and it appears to be a safe procedure for retinal neovascular diseases.


OBJETIVOS: Avaliar a toxicidade do bevacizumabe na retina neurossensorial e epitélio pigmentado da retina (EPR) em olhos de coelhos não albinos pelos estudos histológicos. MÉTODOS: Trinta olhos de 15 coelhos foram distribuídos em três grupos: 10 olhos no grupo placebo (P), que recebeu uma injeção intravítrea de 0,1 ml de solução salina balanceada (SSB); 10 olhos no grupo 1, que recebeu uma injeção intravítrea de 1,25 mg (0,1 ml) de bevacizumabe; e 10 olhos no grupo 2, que recebeu uma injeção intravítrea de 2,5 mg (0,1 ml) de bevacizumabe. Os coelhos tiveram seus dois olhos enucleados sob anestesia geral e submetidos à eutanásia 90 dias após a injeção. Foi realizada avaliação histológica na retina neurossensorial e no epitélio pigmentado da retina e seus aspectos morfológicos e espessuras das camadas retinianas foram analisadas. RESULTADOS: Não foi observada diferença significante entre a morfologia histológica e espessura das camadas retinianas entre o grupo P (SSB) e os grupos 1 e 2 (bevacizumabe 1,25 mg e 2,5 mg, respectivamente). CONCLUSÃO: Após um seguimento de 90 dias, uma única injeção intravítrea de bevacizumabe com 1,25 e 2,5 mg não levou a danos histológicos na retina neurossensorial e epitélio pigmentado da retina em olhos de coelhos não albinos e parece ser um procedimento seguro para o tratamento das doenças neovasculares da retina.


Subject(s)
Animals , Female , Male , Rabbits , Angiogenesis Inhibitors/adverse effects , Antibodies, Monoclonal/adverse effects , Retinal Pigment Epithelium/drug effects , Angiogenesis Inhibitors/administration & dosage , Antibodies, Monoclonal/administration & dosage , Models, Animal , Retina/drug effects , Retina/pathology , Retinal Pigment Epithelium/pathology
2.
Arq. bras. oftalmol ; 71(1): 75-78, jan.-fev. 2008. tab
Article in Portuguese | LILACS | ID: lil-480022

ABSTRACT

OBJETIVO: Avaliar se a opacificação de cápsula posterior (OCP) influenciaria na análise da camada de fibras nervosas pela polarimetria "scanning laser" (GDx). MÉTODOS: Trinta e sete pacientes pseudofácicos não glaucomatosos foram submetidos a análise da camada de fibras nervosas pelo GDx antes e após a realização de capsulotomia com Nd:YAG laser. RESULTADOS: Em cinco olhos, o GDx não conseguiu imagens aceitáveis pelos parâmetros de aquisição do aparelho. Em todos os outros, não foi observada diferença significante entre os valores médios das variáveis antes e após a realização da capsulotomia posterior. CONCLUSÃO: A presença de OCP em graus moderados e/ou quando há imagens aceitáveis em pacientes pseudofácicos não influencia o resultado da análise das imagens das fibras do nervo óptico pelo GDx. Apenas intensos graus de OCP que impeçam a obtenção de imagem analisável pelo aparelho inviabilizam o exame.


PURPOSE: To evaluate if posterior capsule opacification (PCO) would alter the analysis of nerve fiber layer using the scanning laser polarimetry (GDx). METHODS: Pseudophakic non-glaucomatosous eyes (37 patients) underwent nerve fiber layer analysis using GDx before and after posterior capsulotomy with Nd:YAG Laser. RESULTS: In five eyes, GDx did not obtain acceptable images using the device's parameters of acquisition. In the others, mean variable values did not reach significant difference before and after posterior capsulotomy. CONCLUSION: Moderate degrees of PCO and/or acceptable images in pseudophakic patients do not alter the analysis of nerve fiber layer by GDx. Only intense degrees of PCO that hinder analyzable images make the examination impracticable.


Subject(s)
Aged , Aged, 80 and over , Female , Humans , Male , Middle Aged , Lasers , Lens Capsule, Crystalline/innervation , Nerve Fibers/pathology , Pseudophakia/pathology , Diagnostic Techniques, Ophthalmological , Lens Capsule, Crystalline/pathology , Lens Capsule, Crystalline/surgery , Pseudophakia/surgery , Visual Field Tests
3.
An. Fac. Med. Univ. Fed. Pernamb ; 51(2): 110-113, dez. 2006. tab
Article in Portuguese | LILACS | ID: lil-463414

ABSTRACT

O trabalho teve por objetivo avaliar a possível associação entre as alterações laboratoriais com edema macular, em portadores de retinopatia diabética. Foi realizado estudo tipo corte transversal. Incluiu-se 103 pacientes diabéticos, atendidos na Fundação Altino Ventura, sendo 54 com diagnóstico de retinopatia diabética com edema macular (grupo I) e 49 com retinopatia diabética sem edema macular (grupo II). A presença de edema macular em portadores de retinopatia diabética esteve associada significantemente com: hiperglicemia de jejum; hipercolesterolemia total; hipercolesterolemia LDL; hipoproteinemia total e hipoalbuminemia. Além do tratamento direto com fotocoagulação a laser, injeção de triancinolona intra-vítreo ou vitrectomia posterior, deve ser tentado o controle adequado das alterações laboratoriais como hiperglicemia, hipercolesterolemia, hipoproteinemia total e hipoalbuminemia para o manejo do edema macular diabético


Subject(s)
Macular Edema/drug therapy , Risk Factors , Diabetic Retinopathy/epidemiology , Serum Albumin/isolation & purification , Blood Glucose , Cross-Sectional Studies , Hyperglycemia , Logistic Models , Serologic Tests , Triamcinolone
4.
Arq. bras. oftalmol ; 69(5): 671-674, set.-out. 2006. tab
Article in Portuguese, English | LILACS | ID: lil-439311

ABSTRACT

OBJETIVO: Avaliar os resultados visuais e a freqüência de vítreo-retinopatias e descolamento de retina em pacientes, com e sem fotocoagulação profilática pré-operatória da retina pré-equatorial, submetidos à extração de cristalino translúcido (ECT) para correção de miopia. MÉTODOS: Trinta e cinco pacientes (60 olhos) foram submetidos à extração de cristalino translúcido na Fundação Altino Ventura com tempo mediano de acompanhamento de 20,5 meses, sendo divididos em 3 grupos: Grupo I (22 olhos) submetidos à fotocoagulação da retina periférica 360° pré-operatória; Grupo II (8 olhos) submetidos à fotocoagulação pré-operatória circundando lesões predisponentes e Grupo III (30 olhos) não submetidos à fotocoagulação pré-operatória. Foram avaliados a acuidade visual corrigida (AVL c/c), o equivalente esférico refracional (EE) e a presença de membrana neovascular sub-retiniana (MNVSR), lesões predisponentes e descolamento de retina (DR) pré e pós-operatórios. RESULTADOS: O valor mediano da acuidade visual corrigida AVLc/c melhorou de 0,2 no pré-operatório para 0,5 no pós-operatório e o equivalente esférico refracional EE de -17DE para -1,7DE. Não houve casos de descolamento de retina, mas surgiram áreas de tração vítreo-retiniana em 4 olhos (2 submetidos ao laser 360° e 2 olhos não submetidos ao laser) e 1 caso de membrana neovascular sub-retiniana. CONCLUSÃO: A extração de cristalino translúcido mostrou-se cirurgia eficaz e previsível nas reduções de altas miopias e, ainda, procedimento aparentemente seguro em pacientes com e sem fotocoagulação profilática da retina pré-equatorial. Tempo de acompanhamento maior dos pacientes e o aumento da amostra estudada podem ratificar sua segurança como procedimento refrativo.


PURPOSE: To evaluate visual results and vitreoretinopathy and retinal detachment frequencies in patients with and without prophylactic pre-equatorial retinal photocoagulation, who underwent clear lens extraction (CLE) to correct myopia. METHODS: Thirty-five patients (60 eyes) that underwent clear lens extraction at the "Fundação Altino Ventura" had median follow-up of 20.5 months. They were classified into 3 groups: Group I that was submitted to preoperative 360° preequatorial retinal photocoagulation; Group II that was submitted to prophylactic photocoagulation around predisposing lesions; and Group III that was not submitted to preoperative retinal photocoagulation. The presence of corrected visual acuity (CVA), refractional spherical equivalent (RSE) and choroidal neovascularization (CNV), predisposing lesions and retinal detachment (RD) was evaluated. RESULTS: Median corrected visual acuity value rose from 0.2 in the preoperative period to 0.5 in the postoperative period and refractional spherical equivalent decreased from -17SD to -1.7SD. There was no retinal detachment, but vitreous retinal traction areas appeared in 4 eyes (2 submitted to 360° laser and 2 not submitted to laser) and 1 case of choroidal neovascularization also occurred. CONCLUSIONS: Clear lens extraction was an effective and predictable surgery to reduce myopias and an apparently safe procedure in patients with and without prophylactic preequatorial retinal photocoagulation. A longer follow-up in a larger group may validate its safety as a refractive surgery.


Subject(s)
Humans , Adult , Middle Aged , Lens, Crystalline/surgery , Myopia/surgery , Retinal Diseases/surgery , Vitrectomy/methods , Choroidal Neovascularization/surgery , Epidemiologic Methods , Laser Coagulation/adverse effects , Postoperative Complications , Preoperative Care , Refractive Errors/surgery , Retinal Detachment/surgery , Retinal Diseases/pathology , Visual Acuity/physiology , Vitrectomy/standards , Vitreoretinopathy, Proliferative/surgery
5.
Arq. bras. oftalmol ; 69(5): 675-678, set.-out. 2006. tab
Article in Portuguese, English | LILACS | ID: lil-439312

ABSTRACT

OBJETIVO: Avaliar as alterações de campo visual em usuários crônicos de tabaco e álcool por meio da perimetria azul-amarelo estratégia 10-2. MÉTODOS: Quarenta e dois olhos de vinte e um voluntários usuários de tabaco e álcool, todos do gênero masculino, foram selecionados após exame oftalmológico completo e normal, sendo submetidos a perimetria azul-amarelo estratégia 10-2. Quinze voluntários participaram do grupo controle. A análise dos dados foi realizada mediante gráfico da profundidade do defeito e número de pontos alterados. RESULTADOS: Observou-se que 40 olhos (95,3 por cento) dos usuários crônicos de tabaco e álcool, apresentaram maior freqüência de alterações no gráfico de profundidade do defeito (>10dB) e 27 olhos (64,3 por cento) apresentaram número de pontos alterados (>10 pontos), (p<0,0001). Todos os voluntários que apresentaram alterações no gráfico de profundidade do defeito e número de pontos alterados apresentavam menos que 10dB e 10 pontos alterados, respectivamente. CONCLUSÃO: Foram observados maiores números de pontos alterados e profundidade do defeito refletindo alterações nas células do sistema parvocelular, responsáveis pela função de cores nos pacientes usuários crônicos de tabaco-álcool, por meio da perimetria azul-amarelo 10-2.


PURPOSE: To evaluate the visual field changes in blue-on-yellow perimetry (B/Y) strategy 10-2 in alcohol and tobacco smoking consumers. METHODS: Forty-two eyes of twenty-one users were studied. Fifteen individuals were used as a control group. All volunteers were males. After normal ophthalmologic examinations, central 10-2 (B/Y) was performed in both eyes. Analysis of the results was performed through the alterations in the depth graph defect and number of altered points. RESULTS: It was found that the majority of the chronic alcohol and tobacco smoking consumers had a greater frequency of alterations in the depth graph defect; 40 eyes (95.3 percent), (>10dB), and 27 eyes (64.3 percent) showed a number of altered points, (>10 points), (p<0.0001). All those who were used as a control group showed alterations in the depth graph defect and number of altered points, but had less than 10dB and 10 altered points, respectively. CONCLUSION: A higher number of abnormal points and depth graph defects and number of altered points were observed in alcohol and tobacco smoking consumers reflecting a higher number of alterations in the cells of the parvocellular system, responsible for color function, by B/Y perimetry.


Subject(s)
Humans , Male , Adult , Middle Aged , Alcoholism/complications , Color Vision Defects/diagnosis , Smoking/adverse effects , Visual Field Tests , Visual Fields/physiology , Age Distribution , Case-Control Studies , Chi-Square Distribution , Color Vision Defects/etiology , Prospective Studies , Sex Distribution , Visual Field Tests
6.
Arq. bras. oftalmol ; 69(3): 361-364, maio-jun. 2006. tab
Article in Portuguese | LILACS | ID: lil-433800

ABSTRACT

OBJETIVO: Avaliar a variação do astigmatismo entre o pré-operatório, 1° mês e 12° mês pós-operatórios dos pacientes submetidos à cirurgia de catarata, com realização de incisões relaxantes limbares para redução do astigmatismo pré-operatório. MÉTODOS: Foram avaliados 16 pacientes submetidos a cirurgia de catarata pela técnica de facoemulsificação através de incisão escleral tunelizada de 5,5 mm, na Fundação Altino Ventura, no período entre abril e julho de 2002, na qual foram realizados incisões relaxantes no limbo (IRL), seguindo o nomograma modificado de Gills (1D - 1 IRL de 6 mm; 1-2D - 2 IRL de 6 mm; 2-3D - 2 IRL de 8 mm), nos meridianos corneanos mais curvos determinados por topografia corneana pré-operatória. RESULTADOS: Ocorreu redução significante do astigmatismo pré-operatório no 1° mês pós-operatório, no grupo de 2 incisões relaxantes no limbo de 6 mm (57 por cento do astigmatismo topográfico e 87 por cento do refracional) e o de 2 incisões relaxantes no limbo de 8 mm (50 por cento do astigmatismo topográfico e 65 por cento do refracional), mantendo-se sem alteração significante este astigmatismo até o 12° mês pós-operatório. O grupo de 1 incisão relaxante no limbo de 6 mm não alcançou redução significante do astigmatismo, no entanto, não houve alteração significante até o 12° mês pós-operatório. Não foram observadas, ainda, complicações pós-operatórias como "glare", aniseiconia, diplopia, desconforto, infecção da ferida e afinamento ou ectasia corneana. CONCLUSÃO: A realização de 2 incisões relaxantes no limbo de 8 e 6 mm, para correção de astigmatismo pré-operatório de 2 a 3 e 1 a 2 dioptrias, respectivamente, mostraram-se eficazes, seguras e com efeito estável ao longo do primeiro ano de acompanhamento pós-operatório. A realização de 1 incisão relaxante no limbo de 6 mm para redução de 1 dioptria de astigmatismo pré-operatório não se mostrou eficaz, no entanto, não levou a complicações pós-operatórias significativas.


Subject(s)
Humans , Astigmatism/surgery , Lens Implantation, Intraocular , Limbus Corneae/surgery , Phacoemulsification/methods , Corneal Topography , Follow-Up Studies , Treatment Outcome
7.
An. Fac. Med. Univ. Fed. Pernamb ; 47(2): 135-139, 2002. ilus, tab, graf
Article in Portuguese | LILACS | ID: lil-343060

ABSTRACT

Foi objeto desse estudo examinar a posição das alças das lentes intra-ocular (LIOs) com fixação no sulco ciliar e analisar o envolvimento delas com outras estruturas intra-oculares, além de eventuais complicações. O estudo foi realizado no Hospital de Olhos de Pernambuco e Fundação Altino ventura. Foram estudados 25 olhos de pacientes previamente afácicos. Os olhos com LIOD foram saturados através da fixação trans-escleeral e examinados nos pós operatório pela biomicroscopia ultra-sônica. Nove(36por cento) eram homens e 16 (sessenta e quatro por cento )mulheres. Doze (48por cento) cirurgias foram realizadas nos olhos direitos e 13 (52por cento) nos esquerdos. A média de seguimento foi de 22,5 meses (DP=l5,3). A melhor correção visual no pós-operatório foi de 20/50 ou melhor em 52por cento dos olhos, e 20/30 ou melhor 40por cento dos olhos. Todas as alças foram localizadas nos 25 olhos. As posições das 50 alças foram determinadas. Observou-se que das 50 alças (25LIOs), 6(12por cento) estavam localizados no sulco escleral. Das 44 alças (88por cento) fora do sulco ciliar, 19(43por cento) estavam posterior ao sulco ciliar e 11 (25por cento) estavam anterior ao sulco ciliar. Demonstrou-se, através da biomicroscopia ultra-sonica, que a tecnica de fixação trans-escleral é procedimento que dificulta a colocação das alças de lentes intra-oculares na sua posição adequada


Subject(s)
Humans , Male , Female , Adult , Middle Aged , Lenses, Intraocular , Prostheses and Implants , Ultrasonography, Interventional , Anterior Chamber , Lenses, Intraocular
SELECTION OF CITATIONS
SEARCH DETAIL